Hysol KL-G200S | Black Epoxy Mold Compound

Harmonization Code : 3907.30.00.90 |   Polyacetals, other polyethers and epoxide resins, in primary forms; polycarbonates, alkyd resins, polyallyl esters and other polyesters, in primary forms : Epoxide resins : Other
Main features
  • MSL 1 260°C
  • Low Cost of Ownership for Halogen free
  • Designed for DO214 (SMA, SMB & SMX) packages

Product Description

Hysol KL-G200S is a black, halogen-free, semiconductor grade epoxy molding compound. It provides the lowest cost of ownership for a "non-halogen containing" epoxy molding compound. It works on surface mounted diodes such as D0214 in various sizes (SMA, SMB, SMC) and other low end discrete semiconductor and sensor packages. 

Hysol KL-G200S passes MSL1 260°C. It is an epoxy molding compound that contains no bromine, antimony or phosphorus flame retardant. This product is designed to achieve JEDEC Level 1 requirements, at 260°C reflow temperature and provides the lowest cost of ownership with superior moldability and reliability. To top this up, it meets UL 94 V-0 Flammability at 6.35mm thickness.

Product Family
KL-G200S Black  
Pellet
35 mm
21 gr

Catalog Product

Unlike other products we offer, the products listed on this page cannot currently be ordered directly from the website.
Shipping in 12 weeks Shipping in 12 weeks Shipping in 12 weeks

Technical Specifications

General Properties
Color
Color
The color
Black
Filler Content 77 %
Filler Size Cut 75 µm
Specific Gravity
Specific Gravity
Specific gravity (SG) is the ratio of the density of a substance to the density of a reference substance; equivalently, it is the ratio of the mass of a substance to the mass of a reference substance for the same given volume.

For liquids, the reference substance is almost always water (1), while for gases, it is air (1.18) at room temperature. Specific gravity is unitless.
1.95
Shelf Life
Shelf Life @ 5°C 365 days
Chemical Properties
Moisture absorption 0.5 %
Ionic Content
Chloride (Cl-)
Chloride (Cl-)
The amount of Chloride (Cl-) ion extracted from the product in parts per million (ppm)
8 ppm
Sodium (Na+)
Sodium (Na+)
The amount of Sodium (Na+) ion extracted from the product in parts per million (ppm)
3 ppm
Physical Properties
Spiral Flow @ 175°C 80 cm
Thermal Properties
Glass Transition Temperature (Tg)
Glass Transition Temperature (Tg)
The glass transition temperature for organic adhesives is a temperature region where the polymers change from glassy and brittle to soft and rubbery. Increasing the temperature further continues the softening process as the viscosity drops too. Temperatures between the glass transition temperature and below the decomposition point of the adhesive are the best region for bonding.

The glass-transition temperature Tg of a material characterizes the range of temperatures over which this glass transition occurs.
175 °C
Thermal Conductivity
Thermal Conductivity
Thermal conductivity describes the ability of a material to conduct heat. It is required by power packages in order to dissipate heat and maintain stable electrical performance.

Thermal conductivity units are [W/(m K)] in the SI system and [Btu/(hr ft °F)] in the Imperial system.
1.4 W/m.K
UL 94 Rating
UL 94 Rating
Flammability rating classification.
It determines how fast a material burns or extinguishes once it is ignited.

HB: slow burning on a horizontal specimen; burning rate less than 76 mm/min for thickness less than 3 mm or burning stops before 100 mm
V-2: burning stops within 30 seconds on a vertical specimen; drips of flaming particles are allowed.
V-1: burning stops within 30 seconds on a vertical specimen; drips of particles allowed as long as they are not inflamed.
V-0: burning stops within 10 seconds on a vertical specimen; drips of particles allowed as long as they are not inflamed.
5VB: burning stops within 60 seconds on a vertical specimen; no drips allowed; plaque specimens may develop a hole.
5VA: burning stops within 60 seconds on a vertical specimen; no drips allowed; plaque specimens may not develop a hole
V0
Coefficient of Thermal Expansion (CTE)
Coefficient of Thermal Expansion (CTE), α1
Coefficient of Thermal Expansion (CTE), α1
CTE α1 (alpha 1) is the slope of the Coefficient of thermal expansion in a temperature range below the Glass transition temperature (Tg).

It explains how much a material will expand until it reaches Tg.
20 ppm/°C
Coefficient of Thermal Expansion (CTE), α2
Coefficient of Thermal Expansion (CTE), α2
CTE α2 (alpha 2) is the slope of the Coefficient of thermal expansion in a temperature range above the Glass transition temperature (Tg).

It explains the extent to which a material will expand after it passes Tg.
78 ppm/°C
Gel Time
Gel Time @ 175°C / 347°F 20 s
Electrical Properties
Volume Resistivity
Volume Resistivity
Volume resistivity, also called volume resistance, bulk resistance or bulk resistivity is a thickness dependent measurement of the resistivity of a material perpendicular to the plane of the surface.
1.8x1016 Ohms⋅cm
Water Extract Data
Conductivity 20 mmhos/cm
Dissipation Factor
Dissipation Factor @ 25°C /1000 kHz 3.44
Dielectric Constant
Dielectric Constant @ 1000 kHz 3.62
Mechanical Properties
Molded Shrinkage 0.26 %
Water Extract Data
pH of extract 5
Flexural Modulus
Flexural Modulus @ 25°C 15000 N/mm2
Flexural Strength
Flexural Strength @ 25°C
Flexural Strength @ 25°C
Flexural strength, also known as modulus of rupture, or bend strength, or transverse rupture strength is a material property, defined as the stress in a material just before it yields in a flexure test. This is the flexural strength tested at Room Temperature, 25°C
140 N/mm2
Hardness
Hot Hardness, Shore D @ 175°C 88
Curing Conditions
Transfer Pressure 40 - 100 kg/cm2
Transfer Time 10 - 20 s
Post Mold Cure
Post Mold Cure @ 175°C / 347°F 2 - 6 hrs
Curing Schedule
Curing Time @ 175°C / 347°F (Automold) 20 - 60 s
Curing Time @ 175°C / 347°F (Conventional Mold) 40 - 90 s
Curing Time @ 190°C / 374°F (Automold) 30 - 60
Mold Temperature 150 - 195 °C
Preheat Temperature 80 - 90 °C