LOCTITE ABLESTIK 2025DNP

Harmonization Code : 3506.10.00.00 |   Prepared glues and other prepared adhesives, not elsewhere specified or included; products suitable for use as glues or adhesives, put up for retail sale as glues or adhesives, not exceeding a net weight of 1 kg
Main features
  • Excellent dispense capabilities
  • For mother die in array packaging
  • 260ºC reflow capability for Pb-free applications

Product Description

LOCTITE® ABLESTIK ABP 2025DNP is a proprietary hybrid chemistry-based, red-colored, non-conductive die attach adhesive formulated for use in advanced semiconductor array packaging, including PBGA, Flex BGA, and stacking BGA configurations. As a PFAS-free alternative to ABLESTIK 2025D, it delivers robust adhesion, excellent thermal stability, and reliable performance under high-temperature, high-humidity, and Pb-free reflow environments.

This heat-curable adhesive exhibits minimum bleed, strong hot/wet die shear strength, and superior electrical insulation, making it ideal for sensitive, high-reliability electronics.

 

Recommended cure schedule

  • 30 minutes ramp to 175°C + 15 minutes @ 175°C in N2

 

Product Family
2025DNP  
10cc syringe

Catalog Product

Unlike other products we offer, the products listed on this page cannot currently be ordered directly from the website.
Shipping in 12 weeks Shipping in 12 weeks In stock

Technical Specifications

General Properties
Density (g) 1.4 g/cm3
Work life @25°C
Work life @25°C
Work life is the amount of time we have to work with a material until it is no longer able to be easily worked and applied on a substrate.

It is based on the change in viscosity and it can rely on the application requirements.
24 hours
Thermal Properties
Glass Transition Temperature (Tg)
Glass Transition Temperature (Tg)
The glass transition temperature for organic adhesives is a temperature region where the polymers change from glassy and brittle to soft and rubbery. Increasing the temperature further continues the softening process as the viscosity drops too. Temperatures between the glass transition temperature and below the decomposition point of the adhesive are the best region for bonding.

The glass-transition temperature Tg of a material characterizes the range of temperatures over which this glass transition occurs.
36 °C
Thermal Conductivity
Thermal Conductivity
Thermal conductivity describes the ability of a material to conduct heat. It is required by power packages in order to dissipate heat and maintain stable electrical performance.

Thermal conductivity units are [W/(m K)] in the SI system and [Btu/(hr ft °F)] in the Imperial system.
0.3 W/m.K
Electrical Properties
Volume Resistivity
Volume Resistivity
Volume resistivity, also called volume resistance, bulk resistance or bulk resistivity is a thickness dependent measurement of the resistivity of a material perpendicular to the plane of the surface.
1.4x1016 Ohms⋅cm
Chemical Properties
Moisture absorption 0.4 %
Physical Properties
Thixotropic index
Thixotropic index
Thixotropic Index is a ratio of a material s viscosity at two different speeds in Ambient temperature, generally different by a factor of ten.

A thixotropic material s viscosity will decrease as agitation or pressure is increased. It indicates the capability of a material to hold its shape. Mayonnaise is a great example of this. It holds its shape very well, but when a shear stress is applied, the material easily spreads.

It helps in choosing a material in accordance to the application, dispense method and viscosity of a material.
4.4
Viscosity
Viscosity
Viscosity is a measurement of a fluid’s resistance to flow.

Viscosity is commonly measured in centiPoise (cP). One cP is defined as
the viscosity of water and all other viscosities are derived from this base. MPa is another common unit with a 1:1 conversion to cP.

A product like honey would have a much higher viscosity -around 10,000 cPs-
compared to water. As a result, honey would flow much slower out of a tipped glass than
water would.

The viscosity of a material can be decreased with an increase in temperature in
order to better suit an application
13,500 mPa.s